AC TRANSMITTERS
MANUFACTURED TO MOD STANDARDS
APPLICATIONS
• Suitable for wide variety of rotary
linear speed measurement/control
• Industrial Process System
• Diesel Engines
CONSTRUCTION
• Cast Aluminium Housing as Standard
• Gunmetal alternative for hazardous
enviroments
DRIVING TORGUE
600 grm cm for single phase
150 grm cm for three phase
OUTPUT OPTIONS
OUTPUT MAX LOAD
AC 1v/100 rpm 60 mA
AC 5v/100 rpm 10 mA
AC 0,5v/100 rpm 20 mA
DC 2,5v/100 rpm 4 mA
(Three phase rectified)
Multiple receivers can be used with each
transmitter
OPERATING SPEED LIMIT
1v/100 and 5v/100rpm 800 - 8000 rpm
0,5v/100 rpm 800 - 7500 rpm
2,5v/100 rpm (Rectified) 275 - 3000 rpm
GEARBOX RATIOS
HD 1: 5 - 22, 1: 10 - 2
LD 1: 2, 1: 4, 1: 6
Visit the Record Electrical Associates Ltd website for more information on AC Transmitter Alternators & Generators