How Does The Air Flow Click Board™ Work? The Air Flow Click Board™ as its foundation uses the LHDULTRAM012UB3, an LHD ULTRA series flow-based 2-in-1 differential pressure sensor from TE Connectivity Measurement Specialties. It consists of two combined calorimetric micro-flow channels and two sensor elements on a single chip. The first sensing element ensures precise measurement of low differential pressures with high resolution, and the second sensing element is optimized for pressures in the upper measuring range. A fast-response 24-bit onboard controller delivers precise measurement results across the entire dynamic measuring range from 0 to 1250Pa. The specific concept of the LHDULTRAM012UB3 ensures continuous operation that is highly reliable and economically efficient in addition to the outstanding long-term stability, precision with patented real-time offset compensation, and linearization techniques. The LHD ULTRA's high flow impedance ensures product-specific insensitivity to dust/moisture as well as minimal flow leakage.
The Air Flow Click Board™ provides the possibility of using both I2C and SPI interfaces with a maximum frequency of 100kHz for I2C and 1MHz for SPI communication. The selection can be made by positioning SMD jumpers labelled as COMM SEL to an appropriate position. Note that all the jumpers' positions must be on the same side, or else the Click board™ may become unresponsive.
While the I2C interface is selected, the LHDULTRAM012UB3 allows the choice of the least significant bit (LSB) of its I2C slave address using the SMD jumpers labelled as A0 and A1 to an appropriate position marked as 0 and 1. Also, an additional ready signal, routed on the INT pin of the mikroBUS™ socket, is added, indicating that new data is ready for the host.
The Air Flow Click Board™ can be operated only with a 3.3V logic voltage level. The board must perform appropriate logic voltage level conversion before use with MCUs with different logic levels. However, the Click board™ comes equipped with a library containing functions and an example code that can be used, as a reference, for further development.
SPECIFICATIONS
Type
Pressure
Applications
Can be used for industrial and medical applications that demand high precision, extended measurement range, and the convenience of a single device
On-board modules
LHDULTRAM012UB3 - LHD ULTRA series flow-based 2-in-1 differential pressure sensor from TE Connectivity Measurement Specialties
Key Features
Low power consumption, ultra-low pressure ranges, based on thermal microflow measurement, high flow impedance, outstanding long-term stability, on-chip temperature sensor and barometer, SPI/I2C interfaces, and more
Interface
I2C,SPI
Compatibility
mikroBUS
Click board size
L (57.15 x 25.4 mm)
Input Voltage
3.3V
PINOUT DIAGRAM
This table shows how the pinout of the Air Flow Click Board™ corresponds to the pinout on the mikroBUS™ socket (the latter shown in the two middle columns).
Notes
Pin
Pin
Notes
NC
1
AN
PWM
16
NC
NC
2
RST
INT
15
RDY
Data Ready
SPI Chip Select
CS
3
CS
RX
14
NC
SPI Clock
SCK
4
SCK
TX
13
NC
SPI Data OUT
SDO
5
MISO
SCL
12
SCL
I2C Clock
SPI Data IN
SDI
6
MOSI
SDA
11
SDA
I2C Data
Power Supply
3.3V
7
3.3V
5V
10
NC
Ground
GND
8
GND
GND
9
GND
Ground
ONBOARD SETTINGS AND INDICATORS
Label
Name
Default
Description
LD1
PWR
-
Power LED Indicator
JP1/JP2/JP5
COMM SEL
Left
Communication Interface Selection SPI/I2C: Left position SPI, Right position I2C