eFuse Click Board™
Product Code: MIKROE-4726
How Does The eFuse Click Board™ Work? The eFuse Click Board™ as its foundation uses the STPW12, a programmable electronic power breaker optimized to monitor the input power from STMicroelectronics. The device is designed and optimized to work on 12V power rails, even if the operating supply voltage can range from 10.5V to 18V. Connected in series to the power rail, it can disconnect the electronic circuitry on its output if the power consumption overcomes the programmed limit. The intervention threshold is programmed by the resistor connected by the RSET terminal. When this happens, the STPW12 automatically opens the integrated power switch and disconnects the load. The overcoming of the power limit threshold is signaled on the monitor/fault pin on the onboard header pin labelled as VMON. The monitor/fault pin is proportional to the power, continuously present on the pin, and provides two valuable signals for the real-time control of the device and application status. After a particular delay time, programmable by the user, the STPW12 automatically tries again to close the internal switch and re-connect the load.
The eFuse Click Board™ communicates with MCU using two GPIO pins routed on the PWM and RST pins of the mikroBUS™ socket labelled PWM and EN. The device can be enabled or disabled through a dedicated Enable (EN) pin with a direct PWM mode, which can be achieved through an external PWM signal. In this mode, the device's internal power switch can be driven ON/OFF by an external PWM signal, provided to the PWM pin of the STPW12 (square wave, maximum 2kHz, duty cycle 20% - 100%). This approach allows the user to optimize the design power distribution system in terms of accurate power control, choice of isolation material, safety improvements, such as the reduced risk of flammability and easier qualification and certification flow.
The eFuse Click Board™ can be operated only with a 3.3V logic voltage level. The board must perform appropriate logic voltage level conversion before use with MCUs with different logic levels. However, the Click board™ comes equipped with a library containing functions and an example code that can be used, as a reference, for further development.
SPECIFICATIONS
Type
Power Switch
Applications
The eFuse Click Board™ can be used for industrial and consumer applications, fault protection, overcurrent surge protection, and more
On-board modules
STPW12 - programmable electronic power breaker optimized to monitor the input power from STMicroelectronics
Key Features
Real-time input power sensing, undervoltage lockout, PWM mode, thermal shutdown, enable function, short-circuit current limit, and more
Interface
GPIO,PWM
Compatibility
mikroBUS
Click board size
M (42.9 x 25.4 mm)
Input Voltage
3.3V,External
PINOUT DIAGRAM
This table shows how the pinout of the eFuse Click Board™ corresponds to the pinout on the mikroBUS™ socket (the latter shown in the two middle columns).
Notes
Pin
Pin
Notes
NC
1
AN
PWM
16
PWM
PWM Signal
Enable
EN
2
RST
INT
15
NC
NC
3
CS
RX
14
NC
NC
4
SCK
TX
13
NC
NC
5
MISO
SCL
12
NC
NC
6
MOSI
SDA
11
NC
Power Supply
3.3V
7
3.3V
5V
10
NC
Ground
GND
8
GND
GND
9
GND
Ground
ONBOARD SETTINGS AND INDICATORS
Label
Name
Default
Description
LD1
PWR
-
Power LED Indicator
J1
VMON
Unpopulated
Power Monitoring Header
EFUSE CLICK ELECTRICAL SPECIFICATIONS
Description
Min
Typ
Max
Unit
Supply Voltage VCC
-
3.3
-
V