Specifications Model Hantek-2D82-Auto Vehicle Testing Vehicle Diagnosis Vehicle Diagnostic Function Ignition Primary Ignition (Voltage) Primary Ignition(current) Primary Ignition(Voltage& Current) Primary Ignition (Crankshaft Senser) Primary Ignition&SecondaryIgnition Secondary Secondary Ignition Distributor Type (Plug Lead) Secondary Ignition Distributor Type (King Lead) Secondary DIS (Positive-fired) Secondary DIS or CPC (Negative-fired)) Secondary Coil Output Diagnosis Secondary Ignition&Primary Ignition Sensors Air Flow Meter Air Flow Meter (Hot Wire) Air Flow Meter (Air Vane) Air FlowSensor (BOSCH Diesel) Air Intake PressureSensor (BOSCH Diesel) Camshaft Camshaft (Inductive) Camshaft (AC Excited) Camshaft (Hall Effect) Camshaft (BOSCH Common Rail Diesel) Crankshaft Crankshaft Inductive Running Crankshaft Inductive Cranking Crankshaft Hall Effect Crankshaft Sensor &Primary Ignition Distributor Distributor Pick-up (Hall Effect) Distributor Inductive Pick-up Cranking Distributor Inductive Pick-up Running Lambda Sensors Lambda Sensor Titania Lambda Sensor Zirconia Lambda Sensor Zirconia Pre & Post cat Throttle Position Throttle Position Potentiometer Throttle Position Switch Throttle Pedal Switch (Bosch Diesel) ABS Digital Speed Sensor ABS Analog Speed Sensor Coolant Temperature (5V) Coolant Temperature (GM/Vauxhall Simtec Crash Sensor MAP Analog MAP Digital Hall Effect Road Speed Sensor Accelerator Pedal (Bosch Diesel) Bus Diagnosis CAN Bus CAN Bus Data View CAN Bus Signal Integrity CAN Bus LH Long Capture LIN Bus LIN Bus Engine Petrol Single-point Injector (Voltage) Single-point Injector (Current) Multi-point Injector (Voltage) Multi-point Injector (Current) Injector Voltage & Current Injector Current & Primary Ignition Diesel Common Rail Diesel (Current) Injector Bosch CDi 3 (Current) Injector Bosch Diesel (Idling) Injector Bosch Diesel (Accelerating) Diesel Glow Plugs Electronic Fuel Pump Carbon Canister Solenoid Valve ERG Recirculation Solenoid Valve Stepper Motor Example 1 Stepper Motor Example 2 Idle Speed Control Valve (Rotary) Idle Speed Control Valve (Electromagmetic) Throttle Servomotor (Idling) Throttle Servomotor (Accelerating) Bosch CDi3 Quantity Control Valve Bosch CDi3 Pressure Regulator Valve Variable-Speed Cooling Fan On Variable-Speed Cooling Fan Off Variable Camshaft Valve Timing Startup & Charge Charging Circuits Charging Circuits Current/Voltage Charging Circuits Current/Voltage Starting 24V Charging Circuits Current/Voltage Idling 24V Charging Circuits Alternator AC Ripple/Diode Diagnosis Relative Compression Petrol Relative Compression Diesel Starting Voltage Drop Oscilloscope Bandwidth 80MHz Channel 2CH+DMM+AWG Horizontal Sample Rate Range 250MSa/s(Single-channel), 125MSa/s(Dual-channel) Waveform Interpolation (sin x)/x Record Length 3K samples per dual-channel SEC/DIV Range 5ns/div~500s/div 1, 2, 5 sequence Vertical A/D Converter 8-bit resolution,each channel sampled simultaneously VOLTS/DIV Range 10mV/div~10V/divat input BNC Bandwidth Limit, typical 20MHz Low Frequency Response (-3db) ≤10Hz at BNC Rise Time at BNC, typical ≤5ns DC Gain Accuracy ±3% for Normal or Average acquisition mode, 10V/div to 10mV/div Note: Bandwidth reduced to 6MHz when using a 1X probe.
Acquisition
Acquisition Modes
Normal
Trigger
Type
Edge
Mode
Auto, Normal, single
Level
±4 divisions from center of screen
Trigger Level Accuracy
0.2div × volts/div within ±4 divisions from center of screen
Slope
Rising, Falling, Rising & Falling
Source
CH1/CH2
Input
Coupling
DC, AC or GND
Input Impedance,
25pF±3 pF, 1MΩ±2%
DC coupled
Probe Attenuation
1X, 10X
Supported Probe Attenuation Factors
1X, 10X, 100X, 1000X
Maximum Input Voltage
150VRMS
Measurement
Cursor
Voltage difference between cursors: △V
Time difference between cursors: △T
Automatic Measurements
Frequency, Amplitude
Arbitrary Waveform Generator
Waveform Frequency
Sine: 1Hz~25MHz
Square: 1Hz~10MHz
Ramp: 1Hz~1MHz
EXP: 1Hz~5MHz
Sampling
250MSa/s
Amplitude
2.5Vpp(50Ω)
5Vpp(High impedance)
Frequency Resolution
0.001
Channel
1CH waveform output
Waveform Depth
512Sa
Vertical Resolution
12 bit
Frequency Stability
<30ppm
Output Impedance
50 Ω
Multimeter
Maximum Resolution
4000 Counts
DMM Testing Modes
Voltage,Current,Resistance,Capacitance,Diode &On-Off
Maximum Input Voltage
AC:600V, DC: 800V
Maximum Input Current
AC: 10A, DC:10A
Input Impedance
10MΩ
Measurement Term
Range
Accuracy
Resolution
DC Voltage
400.00mV
± (0.8% + 5)
100uV
4.000V
1mV
40.00V
10mV
400.0V
100mV
600.0V
± (1% + 2)
1V
Overload protection: 400mV: 250V, other: 600Vrms.
AC Voltage
4.000V
± (1.2% + 5)
1mV
40.00V
10mV
400.0V
100mV
600.0V
±(1.5% + 5)
1V
Frequency: 40Hz~400Hz;
Frequency of 400V and 600V: 40Hz~100Hz
DC Current
40.00mA
± (1% + 2)
10uA
200.0mA
± (1.5% + 2)
100uA
4.000A
± (1.8% + 2)
1mA
10.00A
± (3% + 2)
10mA
Overload protection:
self restoring fus