Hantek DSO-1102E 2-ch, 100MHz 2M Sample Handheld Oscilloscope
Product Code: DSO-1102E
Specifications Model DSO-1072E DSO-1102E DSO-1152E DSO-1202E Acquisition Sample Modes Real-Time Sample Acquisition Modes Normal Normal data only Peak Detect High-frequency and random glitch capture Average Waveform Average, selectable 4,8,16,32,64,128 Inputs Inputs Coupling AC, DC, GND Inputs Impedance 1MΩ ±2% ‖ 20pF ±3pF Probe Attenuation 1X, 10X Supported Probe Attenuation Factor 1X, 10X, 100X, 1000X Maximum Input Voltage CAT I and CAT II: 300VRMS (10×), Installation Category; CAT III: 150VRMS (1×) Horizontal Sample Rate Range 1GS/s Waveform Interpolation (sin x)/x Record Length 2M SEC/DIV Range 4ns/div~2000s/div, in a 2, 4, 8 sequence 2ns/div~2000s/div, in a 2, 4, 8 sequence Sample Rate and Delay Time Accuracy ±50ppm over any ≥1ms time interval Scanning Speed Range 4ns/div to 8ns/div; (-8div x s/div) to 40ms; 20ns/div to 80μs/div;(-8div×s/div) to 40ms 200μs/div to 40s/div; (-8div×s/div) to 400s 2ns/div to10ns/div; (-4div×s/div) to 20ms; Delta Time Measurement Accuracy (Full Bandwidth) Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns); >16 averages:± (1 sample interval + 100ppm × reading + 0.4ns); Sample interval = s/div ÷ 200 Vertical Vertical Resolution 8-bit resolution, all channel sampled simultaneously Volts Range 2mV/div to 100V/div at input BNC Bandwidth 70MHz 100MHz 150MHz 200MHz Rise Time at BNC( typical) 5ns 3.5ns 2.3ns 1.8ns Analog Bandwidth in Normal and Average modes at BNC or with probe, DC Coupled ±400V (100V/div-20V/div); ±50V (10V/div-5V/div) ±40V (2V/div-500mV/div); ±2V (200mV/div-50mV/div) ±400mV (20mV/div-2mV/div) Math +, -, *, /, FFT FFT Windows:Hanning, Flatop, Rectamgular, Bartlett, Blackman; 1024 sample point Bandwidth Limit 20MHz Low Frequency Response (-3db) ≤10Hz at BNC DC Gain Accuracy ±3% for Normal or Average acquisition mode, 100V/div to 10mV/div.
±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div.
DC Measurement Accuracy,
Average Acquisition Mode
Measurement Type: Average of ≥16 waveforms with vertical position at zero
Accuracy: ± (3% × reading + 0.1div + 1mV) when 10mV/div or greater is selected.
Measurement Type: Average of ≥16 waveforms with vertical position not at zero
Accuracy: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div].
Volts Measurement Repeatability,
Average Acquisition Mode
Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions
Trigger System
Trigger Types
Edge, Video, Pulse, Slope, Over time, Alternative
Trigger Source
CH1, CH2, AC Line
Trigger Modes
Auto, Normal, Single
Coupling Type
DC, AC, HF Reject, LF Reject, Noise Reject
Trigger Sensitivity
(Edge Trigger Type)
DC(CH1,CH2):
1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full;
AC: Attenuates signals below 10Hz ;
HF Reject: Attenuates signals above 80kHz;
LF Reject: Same as the DC-coupled limi
Visit the Debug Store website for more information on Hantek DSO-1102E 2-ch, 100MHz 2M Sample Handheld Oscilloscope