Product Code: DSO-4072C

SpecificationsOscilloscope Model DSO-4202C DSO-4102C DSO-4072C Sample Rate Sample Rate: 1GSa/s Equivalent Sample Rate: 25GSa/s Acquisition Modes Normal Normal data only Peak Detect High-frequency and random glitch capture Average Wavefom Average, selectable 4,8,16,32,64,128 Inputs Inputs Coupling AC, DC, GND Inpits Impendance 1MΩ±2% ‖20pF±3pF Probe Attenuation 1X, 10X Supported Probe Attenuation Factor 1X, 10X, 100X, 1000X Maximum Input Voltage CAT I and CAT II: 300VRMS (10×) CAT III: 150VRMS(1×); Installation Category II: derate at 20dB/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal waveforms, peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these values are exceeded, damage to the oscilloscope may occur. Horizontal Sample Rate Range 1GS/s Waveform Interpolation (sin x)/x Record Length 40K SEC/DIV Range 2ns/div to 40s/div Sample Rate and ±50ppm(at over any ≥1ms time interval) Delay Time Accuracy Position Range 2ns/div to 8ns/div; (-8div x s/div) to 20ms; 20ns/div to 80us/div; (-8div x s/div) to 40ms; 200us/div to 40s/div; (-8div x s/div) to 400s Delta Time Measurement Accuracy(Full Bandwidth) Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns);>16 averages:± (1 sample interval + 100ppm × reading + 0.4ns);Sample interval = s/div ÷ 200 Vertical Vertical Resolution 8-bit resolution, all channel sampled simultaneously Position Range 2mV/div to 10V/div Bandwidth 200MHz 100MHz 70MHz Rise Time at BNC( typical) 1.8ns 3.5ns 5ns Offset Range 2mV/div to 20mV/div, ±400mV; 50mV/div to 200mV/div, ±1V 500mV/div to 2V/div, ±40V; 5V/div to 10V/div, ±50V Math +, -, *, /, FFT FFT Windows: Hanning, Flatop, Rectamgular, Bartlett, Blackman 1024 sample point Bandwidth Limit 20MHz Low Frequency Response (-3db) ≤10Hz at BNC DC Gain Accuracy ±3% for Normal or Average acquisition mode, 10V/div to 10mV/div; ±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div DC Measurement Accuracy,Average Acquisition Mode When vertical displacement is zero, and N ≥16:± (3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected; When vertical displacement is not zero, and N≥16: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 10V/div Volts Measurement Repeatability, Average Acquisition Mode Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions Trigger System Trigger Types Edge, Video, Pulse, Slope, Over time, Alternative Trigger Source CH1, CH2, EXT, EXT/5, AC Line Trigger Modes Auto, Normal, Single Coupling Type DC, AC, Noise Reject, HF Reject, LF Reject Trigger Sensitivity(Edge Trigger Type) DC(CH1,CH2): 1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full; DC(EXT): 200mV from DC to 100MHz; 350mV from 100MHz to 200MHz; DC(EXT/5): 1V from DC to 100MHz;1.75V from 100MHz to 200MHz; AC: Attenuates signals below 10Hz; HF Reject: Attenuates signals above 80kHz; LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz Trigger Level Range CH1/CH2: ±8 divisions from center of screen; EXT: ±1.2V; EXT/5:±6V Trigger Level Accuracy( typical)Accuracy is for signals having rise and fall times ≥20ns CH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen; EXT: ± (6% of setting + 40mV); EXT/5: ± (6% of setting + 200mV); Set Level to 50%(typical) Operates with input signals ≥50Hz Video Trigger Video Trigger Type CH1, CH2: Peak-to-peak amplitude of 2 divisions; EXT: 400mV; EXT/5: 2V Signal Formats and Field Rates, Video Trigger Type Supports NTSC, PAL and SECAM broadcast systems for any field or any line Holdoff Range 100ns ~ 10s Pulse Width Trigger Pulse Width Trigger Mode Trigger when (< , >, = , or ≠); Positive pulse or Negative pulse Pulse Width Trigger Point Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level.Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge.
Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.Less than: The trigger point is the trailing edge.Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width Pulse Width Range 20ns ~ 10s Slope Trigger Slope Trigger Mode Trigger when (< , > , = , or ≠ ); Positive slope or Negative slope Slope Trigger Point Equal: The oscilloscope triggers when the waveform slope is equal to the set slope. Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope. Less than: The osci
ENQUIRY FORM

More Products

  • Sunny Computer Wall Power Supplies - SYS1541 - 15V 1.6A

  • Sunny Computer Wall Power Supplies - SYS1541 - 18V 1.4A

  • Sunny Computer AC Plug - China (SYS1541 Series)

  • Sunny Computer Wall Power Supplies - SYS1541 - 12V 2A