Hantek DSO-5072P 2-ch, 70MHz Oscilloscope

Product Code: DSO-5072P

Specifications Model DSO-5202P DSO-5102P DSO-5072P Acquisition Sample Rate Real-Time Sample: 1GS/s Equivalent Sample: 25GS/s Acquisition Modes Normal Normal data only Peak Detect High-frequency and random glitch capture Average Waveform Average, selectable 4,8,16,32,64,128 Inputs Inputs Coupling AC, DC, GND Inpits Impendance 1MΩ±2% ‖20pF±3pF Probe Attenuation 1X, 10X Supported Probe Attenuation Factor 1X, 10X, 100X, 1000X Maximum Input Voltage CAT I and CAT II: 300VRMS (10×), Installation Category; CAT III: 150VRMS (1×); Installation Category II: derate at 20dB/decade above 100kHz to 13V peak AC at 3MHz* and above.
For non-sinusoidal waveforms, peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these values are exceeded, damage to the oscilloscope may occur. Horizontal Sample Rate Range 500MS/s--1GS/s Waveform Interpolation (sin x)/x Record Length 40K SEC/DIV Range 2ns/div to 80s/div Sample Rate and Delay Time Accuracy ±50ppm(at over any ≥1ms time interval) Offset Range 2ns/div to 8ns/div; (-8div x s/div) to 20ms; 20ns/div to 80us/div; (-8div x s/div) to 40ms; 200us/div to 80s/div; (-8div x s/div) to 400s Delta Time Measurement Accuracy (Full Bandwidth) Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns); >16 averages:± (1 sample interval + 100ppm × reading + 0.4ns); Sample interval = s/div ÷ 200 Vertical Vertical Resolution 8-bit resolution, all channel sampled simultaneously Position Range 2mV/div to 20mV/div, ±400mV; 50mV/div to 200mV/div, ±2V 500mV/div to 2V/div, ±40V; 5V/div to 10V/div, ±50V Bandwidth 200MHz 100MHz 70MHz Rise Time at BNC( typical) 1.8ns 3.5ns 5ns Math +, -, *, /, FFT FFT Windows: Hanning, Flatop, Rectamgular, Bartlett, Blackman; 1024 sample point Bandwidth Limit 20MHz Low Frequency Response (-3db) ≤10Hz at BNC DC Gain Accuracy ±3% for Normal or Average acquisition mode, 10V/div to 10mV/div; ±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div DC Measurement Accuracy, Average Acquisition Mode When vertical displacement is zero, and N ≥16:± (3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected; When vertical displacement is not zero, and N≥16: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 10V/div Volts Measurement Repeatability, Average Acquisition Mode Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions Trigger System Trigger Types Edge, Video, Pulse, Slope, Over time, Alternative Trigger Source CH1, CH2, EXT, EXT/5, AC Line Trigger Modes Auto, Normal, Single Coupling Type DC, AC, Noise Reject, HF Reject, LF Reject Trigger Sensitivity (Edge Trigger Type) DC(CH1,CH2): 1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full; DC(EXT): 200mV from DC to 100MHz; 350mV from 100MHz to 200MHz; DC(EXT/5): 1V from DC to 100MHz;1.

Visit the Debug Store website for more information on Hantek DSO-5072P 2-ch, 70MHz Oscilloscope

ENQUIRY FORM

More Products

  • Sunny Computer Wall Power Supplies - SYS1541 - 15V 1.6A

  • Sunny Computer Wall Power Supplies - SYS1541 - 18V 1.4A

  • Sunny Computer AC Plug - China (SYS1541 Series)

  • Sunny Computer Wall Power Supplies - SYS1541 - 12V 2A