Specifications Model DSO-8072E DSO-8102E DSO-8152E DSO-8202E Bandwidth 70MHz 100MHz 150MHz 200MHz Acquisition Sample Modes Real-Time Sample Acquisition Modes Normal Normal data only Peak Detect High-frequency and random glitch capture Average Waveform Average, selectable 4,8,16,32,64,128 Inputs Inputs Coupling AC, DC, GND Inputs Impendance 1MΩ±2% ‖20pF±3pF Probe Attenuation 1X, 10X Supported Probe Attenuation Factor 1X, 10X, 100X, 1000X Maximum Input Voltage CAT I and CAT II: 300VRMS (10×), Installation Category; CAT III: 150VRMS (1×) Horizontal System Sample Rate Range 1GS/s Waveform Interpolation (sin x)/x Record Length 2M SEC/DIV Range 4ns/div~2000s/div, in a 2, 4, 8 sequence 2ns/div~2000s/div, in a 2, 4, 8 sequence Sample Rate andDelay Time Accuracy ±50ppm over any ≥1ms time interval Scanning Speed Range 4ns/div to 8ns/div; (-8div x s/div) to 40ms;20ns/div to 80μs/div;(-8div×s/div) to 40ms;200μs/div to 40s/div;(-8div×s/div) to 400s; 2ns/div to10ns/div;(-4div×s/div) to 20ms; Delta Time Measurement Accuracy (Full Bandwidth) Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns);>16 averages:± (1 sample interval + 100ppm × reading + 0.4ns);Sample interval = s/div ÷ 200 Vertical System Vertical Resolution 8-bit resolution, all channel sampled simultaneously Volts Range 2mV/div to 100V/div at input BNC Rise Time at BNC( typical) 5ns 3.5ns 2.3ns 1.8ns Analog Bandwidth inNormal and Averagemodes at BNC or with probe, DC Coupled ±400V(100V/div-20V/div); ±50V(10V/div-5V/div);±40V(2V/div-500mV/div); ±2V(200mV/div-50mV/div);±400mV(20mV/div-2mV/div); Math +, -, *, /, FFT FFT Windows: Hanning, Flatop, Rectamgular, Bartlett, Blackman; 1024 sample point Bandwidth Limit 20MHz Low Frequency Response (-3db) ≤10Hz at BNC DC Gain Accuracy ±3% for Normal or Average acquisition mode, 100V/div to 10mV/div.±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div.
DC Measurement Accuracy, Average Acquisition Mode
Measurement Type: Average of ≥16 waveforms with vertical position at zeroAccuracy: ± (3% × reading + 0.1div + 1mV) when 10mV/div or greater is selected.Measurement Type: Average of ≥16 waveforms with vertical position not at zeroAccuracy: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div].
Volts Measurement Repeatability, Average Acquisition Mode
Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions
Trigger System
Trigger Types
Edge, Video, Pulse, Slope, Over time, Alternative
Trigger Source
CH1, CH2, AC Line
Trigger Modes
Auto, Normal, Single
Coupling Type
DC, AC, HF Reject, LF Reject, Noise Reject
Trigger Sensitivity(Edge Trigger Type)
DC(CH1,CH2):1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full;AC: Attenuates signals below 10Hz ;HF Reject: Attenuates signals above 80kHz;LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz.
Trigger Level Range
CH1/CH2: ±8 divisions from center of screen;
Trigger Level Accuracy( typical)Accuracy is for signals having rise and fall times ≥20ns
CH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen;
Set Level to 50%(typical)
Operates with input signals ≥50Hz
Video Trigger
Video Trigger Type
CH1, CH2: Peak-to-peak amplitude of 2 divisions;
Signal Formats and Field Rates
Supports NTSC, PAL and SECAM broadcast systems for any field or any line
Holdoff Range
100ns ~ 10s
Pulse Width Trigger
Pulse Width Trigger Mode
Trigger when (< , >, = , or ≠); Positive pulse or Negative pulse
Pulse Width Trigger Point
Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level.Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.Less than: The trigger point is the trailing edge.Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width
Pulse Width Range
20ns ~ 10s
Slope Trigger
Slope Trigger Mode
Trigger when (< , > , = , or ≠ ); Positive slope or Negative slope
Slope Trigger Point
Equal: The oscilloscope triggers when the waveform slope is equal to the set slope.Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope.Less than: The oscilloscope triggers when the waveform slope is less than the set slope.Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.
Time Range
20ns ~ 10s
Overtime Trigger
Over Time Modee
Rising edge or Falling edge
Time Range
20ns ~ 10s
Alternative Trigger
Trigger on CH1
Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger on CH2
Internal Trigger: Edge, Pulse Width, V
Visit the Debug Store website for more information on Hantek DSO-8152E 2-ch, 150MHz, 2m Sample Handheld Oscilloscope