Heart Rate 2 Click Board™
Product Code: MIKROE-4037
How Does The Heart Rate 2 Click Board™ Work? The Heart Rate 2 Click Board™ is well suited for a wide variety of optical sensing applications, consisting of a single optical readout channel and a precision LED driver current DACs that modulate LED pulses for a variety of optical measurements. The LED current DACs have 8 bits of dynamic range with four programmable full-scale ranges of 31mA, 62mA, 94mA, and 124mA. The LED drivers are low dropout current sources allowing for low-noise, power-supply independent LED currents to be sourced at the lowest supply voltage possible, minimizing LED power consumption. The LED pulse width can be programmed from 14.8μs to 117.3μs to allow the algorithms to optimize SpO2 and HR accuracy at the lowest dynamic power consumption dictated by the application. The optical subsystem Heart Rate 2 Click based on MAXM86161 is composed of ambient light cancellation (ALC), a continuous-time sigma-delta ADC, and proprietary discrete time filter. ALC incorporates a proprietary scheme to cancel ambient light-generated photo diode currents, allowing the sensor to work in high ambient light conditions.
The optical ADC has programmable full-scale ranges of 4μA to 32μA. The internal ADC is a continuous time, oversampling sigma-delta converter with 19-bit resolution. The ADC output data rate can be programmed from 8sps (samples per second) to 4096sps. The MAXM86161 includes a proprietary discrete time filter to reject 50Hz/60Hz interference and changing residual ambient light from the sensor measurements.
Sensor also includes an optical proximity function which could significantly reduce energy consumption and extend battery life when the sensor is not in contact with the skin. MAXM86161 power to a minimum during situations where there is no reflective returned signal. It is also intended to reduce the emitted light to a minimum or even below that perceivable by the human eye.
The native delta-sigma ADC linearity is exceptional. However, the subranging DAC uses a unary architecture which has some mismatch between unit current sources of the DAC and the ADC reference current. This mismatch results in some transfer function nonlinearity (XNL) errors when the sub-DAC code transitions. For this reason, the sub-ranging DAC algorithm is designed to minimize DAC transitions by introducing large hysteresis through the overlapping sub-DAC ranges. Consequently, under normal PPG operation, the sub-DAC does not transition and the linearity of the converter signal is driven entirely by the linear native delta-sigma ADC. In addition to algorithmically reducing the sub-DAC transitions, the MAXM86161 incorporates a self-calibration scheme that can be used to further reduce the sub-DAC XNL errors.
SPECIFICATIONS
Type
Heart Rate,Biometrics
Applications
Ideal solution for the development of various wearable health-related devices, Optimized for In-Ear Applications, Miniature Package for Mobile Applications
On-board modules
MAXM8616 - Single-Supply Integrated Optical Module for HR and SpO2 Measurement
Key Features
Complete Single-Channel Optical Data Acquisition System, Built-In Algorithm Further Enhances Rejection of Fast Ambient Transients, Optimized Architecture for Reflective Heart Rate and SpO2 Monitoring...
Interface
I2C
Compatibility
mikroBUS
Click board size
S (28.6 x 25.4 mm)
Input Voltage
3.3V,5V
PINOUT DIAGRAM
This table shows how the pinout on the Heart Rate 2 Click Board™ corresponds to the pinout on the mikroBUS™ socket (the latter shown in the two middle columns).
Notes
Pin
Pin
Notes
General Purpose
GP
1
AN
PWM
16
NC
NC
2
RST
INT
15
INT
Interrupt
NC
3
CS
RX
14
NC
NC
4
SCK
TX
13
NC
NC
5
MISO
SCL
12
SCL
I2C Clock
NC
6
MOSI
SDA
11
SDA
I2C Data
Power Supply
3.3V
7
3.3V
5V
10
5V
Visit the Debug Store website for more information on Heart Rate 2 Click Board™