Load Cell 6 Click Board™
Product Code: MIKROE-4940
How Does The Load Cell 6 Click Board™ Work? The Load Cell 6 Click Board™ as its foundation uses the MAX11270, a pin programmable, ultra-low power 24-bit ΣΔ ADC that resolves a very high dynamic range from Maxim Integrated, now part of Analog Devices. The MAX11270 achieves excellent 130dB SNR while dissipating an ultra-low 10mW. It allows users to select a programmable gain amplifier with gain settings between 1x to 128x, unity-gain buffer, or connect signals directly to the delta-sigma sampling network. This ADC can resolve micro-volt level changes to the analogue input, making it a good fit for seismic, instrumentation, and ATE applications. The MAX11270 measures a pair of differential analogue inputs (S+, S-) in buffered, direct connect, or PGA. The default configuration is directly connected, with PGA and input buffers powered down. These optional buffers isolate the signal inputs from the switched capacitor sampling network, which allows the MAX11270 to be used with high-impedance sources without compromising the available dynamic range.
The ADC input range is programmable for unipolar (0 to VREF) ranges set by the reference voltage value obtained by the MAX6126, a 3V high-precision voltage reference, also routed to the E+ terminal.
The Load Cell 6 Click Board™ communicates with MCU through a standard SPI interface that enables high clock speeds up to 5MHz. The MAX11270 is highly configurable via the internal registers, accessed via the SPI interface. It operates in two modes: Conversion mode or Register-Access mode selected by the command byte. Those registers include PGA gain selection, offset and gain calibration, and a scalable sample rate to optimize performance. It also offers software-selectable output data rates, up to 12.8ksps with no data latency and 64ksps continuous, to optimize data rate and noise.
In addition, it uses the Reset pin, routed to the RST pin of the mikroBUS™ socket, is used for a complete reset of all digital functions resulting in a Power-On reset default state, while the Data-Ready signal, labelled as RDY and routed to the INT pin of the mikroBUS™ socket, notifies the host MCU when the data is ready. The Sync Reset signal is also used, labelled as SYN, and routed to the PWM pin of the mikroBUS™ socket, which resets both the digital filter and modulator. It also has a GPIO header with two general-purpose pins from the MAX11270 which are user-configurable.
Even though this board uses both mikroBUS™ power rails, this Click Board™ can only be operated with a 3.3V logic voltage level (5V is used only as a voltage reference power supply). The board must perform appropriate logic voltage level conversion before using MCUs with different logic levels. However, the Load Cell 6 Click Board™ equipped comes equipped with a library containing functions and an example code that can be used, as a reference, for further development.
SPECIFICATIONS
Type
Force
Applications
Can be used for weight scale applications in various use cases
On-board modules
MAX11270 - pin programmable, ultra-low power 24-bit ΣΔ ADC that resolves a very high dynamic range from Analog Devices
Key Features
High-resolution for instrumentation applications that require a wide dynamic range, high accuracy for DC measurements, flexible high-performance filter architecture, and more
Interface
SPI
Compatibility
mikroBUS
Click Board™ board size
L (57.15 x 25.4 mm)
Input Voltage
3.3V,5V
PINOUT DIAGRAM
This table shows how the pinout on the Load Cell 6 Click Board™ corresponds to the pinout on the mikroBUS™ socket (the latter shown in the two middle columns).
Notes
Pin
Pin
Notes
NC
1
AN
PWM
16
SYN
Sync Reset
Reset
RST
2
RST
INT
15
RDY
Data-Ready
SPI Chip Select
CS
3
CS
RX
14
NC
SPI Clock
SCK
4
SCK
TX
13
NC
SPI Data OUT
SDO
5
MISO
SCL
12
NC
SPI Data IN
SDI
6
MOSI
SDA
11
NC
Power Supply
3.3V
7
3.3V
5V
Visit the Debug Store website for more information on Load Cell 6 Click Board™