Pressure 19 Click Board™
Product Code: MIKROE-5089
How Does The Pressure 19 Click Board™ Work? The Pressure 19 Click Board™ as its foundation uses the MLX90817, a factory-calibrated absolute pressure sensor delivering ratiometric analog output from Melexis Technologies. The MLX90817 absolute pressure sensor includes a sensing element, analog to digital converter, signal processing part, and digital interface that sends the digital pressure data to the host controller. It measures pressure from 0.2 up to 3bar with pressure accuracy of ±33mbar over a wide operating temperature range at the industry's lowest power. The MLX90817 contains a pressure sensing element that consists of a diaphragm, which reacts to a change in absolute pressure, realized in the silicon chip by wafer bonding on an etched cavity with a built-in reference vacuum. The internal strain increases, in particular at the border of the diaphragm, where piezo-resistive elements have been implanted into the silicon diaphragm forming a Wheatstone bridge, which acts as a transducer.
The front end amplifies the signal from the bridge and performs a coarse offset compensation and an ADC conversion. Then, the DSP executes the compensations over temperature. Furthermore, the digital circuit provides some filtering, the possibility to linearize the pressure signal, and also implements the clamping function, delivering an analog output proportional to the pressure.
The analog output voltage of the MLX90817 can be converted to a digital value using MCP3221, a successive approximation A/D converter from Microchip, using a 2-wire I2C compatible interface, or can be sent directly to an analog pin of the mikroBUS™ socket labelled as AN. Selection can be performed by onboard SMD jumper labelled as AD SEL to an appropriate position marked as AN and ADC. Using MCP3221 and I2C interface, data transfers at rates of up to 100kbit/s in the Standard and 400kbit/s in the Fast Mode.
Since the sensor for operation requires a 5V logic voltage level only, this Click board™ also features the PCA9306 voltage-level translator from Texas Instruments. The I2C interface bus lines are routed to the dual bidirectional voltage-level translator, allowing this Click board™ to work with both 3.3V and 5V MCUs properly.
The Pressure 19 Click Board™ can operate with both 3.3V and 5V logic voltage levels selected via the VCC SEL jumper. This way, it is allowed for both 3.3V and 5V capable MCUs to use the communication lines properly. However, the Click board™ comes equipped with a library containing easy-to-use functions and an example code that can be used, as a reference, for further development.
SPECIFICATIONS
Type
Pressure
Applications
The Pressure 19 Click Board™ can be used for automotive, industrial, and consumer pressure measurements
On-board modules
MLX90817 - absolute pressure sensor from Melexis Technologies
Key Features
Low power consumption, high accuracy, piezoresistive sensing principle, built-in temperature compensation function, allow to process the output signal in analog or digital form, system in package, factory calibrated, and more
Interface
Analog,I2C
Compatibility
mikroBUS
Click board size
S (28.6 x 25.4 mm)
Input Voltage
3.3V or 5V
PINOUT DIAGRAM
This table shows how the pinout of the Pressure 19 Click Board™ corresponds to the pinout on the mikroBUS™ socket (the latter shown in the two middle columns).
Notes
Pin
Pin
Notes
Analog Signal
AN
1
AN
PWM
16
NC
NC
2
RST
INT
15
NC
NC
3
CS
RX
14
NC
NC
4
SCK
TX
13
NC
NC
5
MISO
SCL
12
SCL
I2C Clock
NC
6
MOSI
SDA
11
SDA
I2C Data
Power Supply
3.3V
7
3.3V
5V
10
5V
Power Supply
Ground
GND
8
GND
GND
9
GND
Ground
ONBOARD SETTINGS AND INDICATORS
Label
Name
Default
Description
Visit the Debug Store website for more information on Pressure 19 Click Board™