SPI Isolator 6 Click Board™
Product Code: MIKROE-5265
How Does The SPI Isolator 6 Click Board™ Work? The SPI Isolator 6 Click Board™ as its foundation uses the MAX22345, a four-channel digital isolator with a maximum data rate of 200Mbps from Analog Devices. The MAX22345 provides galvanic isolation for digital signals transmitted between two ground domains and can withstand up to 784Vpeak of continuous isolation and up to 3.75kVRMS for up to 60 seconds. Besides, it also offers low-power operation, high electromagnetic interference (EMI) immunity, and stable temperature performance through Analog's proprietary process technology. Both power pins' wide supply voltage range allows the MAX22345 to be used for level translation and isolation. Because the SPI Isolator 6 Click Board™ represents an isolator for SPI communication, it logically communicates with the MCU precisely through that communication. As already mentioned, the MAX22345 has two power pins for the A and B isolation sides, where it is possible to supply its B side with external voltage in the range of 1.7 to 5.5V by applying it to the terminal marked with VCC_EXT.
In addition to the external power supply terminal, this Click board ™ also possesses another two terminals to which the isolated SPI data communication lines are routed.
The SPI Isolator 6 Click Board™ can operate with both 3.3V and 5V logic voltage levels selected via the VCC SEL jumper. This way, it is allowed for both 3.3V and 5V capable MCUs to use the communication lines properly. However, the Click board™ comes equipped with a library containing easy-to-use functions and an example code that can be used, as a reference, for further development.
SPECIFICATIONS
Type
Isolators,SPI
Applications
Can be used for general SPI-bus isolation, industrial, process and building automation, programmable logic controllers, and many more
On-board modules
MAX22345 - four-channel digital isolator from Analog Devices
Key Features
Reinforced galvanic isolation for SPI communication, up to 200Mbps maximum data rate, withstands 3.75kVRMS for 60s, low power consumption, and more
Interface
SPI
Compatibility
mikroBUS
Click board size
M (42.9 x 25.4 mm)
Input Voltage
3.3V or 5V,External
PINOUT DIAGRAM
This table shows how the pinout of the SPI Isolator 6 Click Board™ corresponds to the pinout on the mikroBUS™ socket (the latter shown in the two middle columns).
Notes
Pin
Pin
Notes
NC
1
AN
PWM
16
NC
NC
2
RST
INT
15
NC
SPI Chip Select
CS
3
CS
RX
14
NC
SPI Clock
SCK
4
SCK
TX
13
NC
SPI Data OUT
SDO
5
MISO
SCL
12
NC
SPI Data IN
SDI
6
MOSI
SDA
11
NC
Power Supply
3.3V
7
3.3V
5V
10
5V
Power Supply
Ground
GND
8
GND
GND
9
GND
Ground
ONBOARD SETTINGS AND INDICATORS
Label
Name
Default
Description
LD1
PWR
-
Power LED Indicator
JP1
VCC SEL
Left
Logic Level Voltage Selection 3V3/5V: Left position 3V3, Right position 5V
SPI ISOLATOR 6 CLICK ELECTRICAL SPECIFICATIONS
Description
Min
Typ
Max
Unit
Supply Voltage
3.3
-
5
V
External Supply Voltage VCC_EXT
1.7
-
5.5
V
Data Rate
-
-
200
Mbps
Isolation Voltage (Continuously)
-
-
784
VRMS
Visit the Debug Store website for more information on SPI Isolator 6 Click Board™