VCP Monitor Click Board™
Product Code: MIKROE-4039
How Does The VCP Monitor Click Board™ Work? The VCP Monitor Click Board™ is power monitor system, which includes precision measurement of current, voltage and power with low-drift. The main IC on the VCP Monitor click is INA260AIPWR. The current-sensing resistor is designed as a 4 wire connected resistor that enables accurate measurements through a force-sense connection. The INA260AIPWR is internally calibrated to ensure that the current-sensing resistor and current-sensing amplifier are both precisely matched to one another. The INA260AIPWR device performs two measurements on power supply bus. The current measurement on LOAD connector, is internally calculated by measuring the voltage developed across a known internal shunt resistor. The features is a physical shunt resistance that is able to withstand current levels higher than the continuous handling limit of 15 A without sustaining damage to the current-sensing resistor or the current-sensing amplifier if the excursions are very brief.
The voltage measurement on SUPPLY connector witch is calculated by measuring the voltage from the external VBUS pin to ground. The voltage monitored range from 0V to 36V
The INA260AIPWR device performs two measurements on power supply bus. The current measurement on LOAD connector, is internally calculated by measuring the voltage developed across a known internal shunt resistor, and voltage measurement on SUPPLY connector wich is calculated by measuring the voltage from the external VBUS pin to ground.
The VCP Monitor click is compatibility with I2C communication protocol. The INA260AIPWR has two slave address selection pins, A0 and A1. For I2C slave address selection, VCP Monitor click has two cross-shape jumpers, first for set pin A0 and second for set A1 pin. One cross-shape jumper has four position for select address pin which can be selected with a SMD 0 ohm resistor, address pin can be connected to GND, VS, SCL or SDA pins. The VCP Monitor click with the two separate jumper on Click board™ user can to set the desired address. The INA260AIPWR provides the opportunity of the 16 possible different I2C addresses.
I2C SLAVE ADDRESS SELECTION
A1
A0
Slave address
GND
GND
1000000
GND
VS
1000001
GND
SDA
1000010
GND
SCL
1000011
VS
GND
1000100
VS
VS
1000101
VS
SDA
1000110
VS
SCL
1000111
SDA
GND
1001000
SDA
VS
1001001
SDA
SDA
1001010
SDA
SCL
1001011
SCL
GND
1001100
SCL
VS
1001101
SCL
SDA
1001110
SCL
SCL
1001111
The INA260AIPWR is supported with ALERT pin, which is connected to the INT pin on mikroBUS™, in order to interrupt the ongoing MCU routine in case of the alert condition. INT pin can be programmed to respond to a user-defined event or to a conversion ready notification.
The voltage level of the logic section can be selected via VCC SEL jumper, between 3.3V and 5V. This allows for both 3.3V and 5V capable MCUs to use the I2C communication lines properly.
SPECIFICATIONS
Type
Current sensor
Applications
VCP Monitor click click is a perfect solution for the development of the Power Managment system, Battery Chargers and Power Supplies.
On-board modules
NA260AIPWR, a digital-output, current, power, and voltage monitor with an I2C and SMBus™-compatible interfacefrom Texas Instruments
Key Features
Current Sense Resistance: 2 mΩ, Tolerance Equivalent to 0.1%, 15-A Continuous From –40°C to +85°C, 16 Programmable Addresses.
Interface
I2C
Compatibility
mikroBUS
Click board size
M (42.9 x 25.4 mm)
Input Voltage
3.3V or 5V
PINOUT DIAGRAM
This table shows how the pinout on VCP Monitor click corresponds to the pinout on the mikroBUS™ socket (the latter shown in the two middle columns).
Notes
Pin
Visit the Debug Store website for more information on VCP Monitor Click Board™